Eu Declaration Of Conformity; Technical Data - EUCHNER STP Serie Mode D'emploi

Masquer les pouces Voir aussi pour STP Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Safety Switch STP...

EU declaration of conformity

The declaration of conformity is part of the oper‑
ating instructions, and it is included as a separate
sheet with the unit.
The original EU declaration of conformity can also
be found at: www.euchner.com
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden‑Echterdingen
Service telephone:
+49 711 7597‑500
Fax:
+49 711 753316
E-mail:
support@euchner.de
Internet:
www.euchner.com
All manuals and user guides at all-guides.com

Technical data

Parameter
Value
Housing material
Reinforced thermoplastic
Degree of protection acc. to
IEC 60529
IP67
Cable entry
IP65
Plug connector SR11
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
‑20 ... +55 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947‑1)
Installation orientation
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
30 N
Retention force
20 N
Actuating force, max.
35 N
Actuation frequency
1,200/h
Switching principle
Slow‑action switching contact
Contact material
Silver alloy, gold flashed
Connection
STP...
Cable entry M20 x 1.5
STP...SR11
Plug connector SR11, 11‑pin+PE
(PE not connected)
Conductor cross‑section
0.34 ... 1.5 mm²
(flexible/rigid)
Operating voltage for optional
L024 24 V
LED indicator
Rated insulation voltage
STP...
U
= 250 V
i
STP...SR11
U
= 50 V
i
Rated impulse withstand voltage
STP...
U
= 2.5 kV
imp
STP...SR11
U
= 1.5 kV
imp
Conditional short‑circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Utilization category acc. to EN 60947‑5‑1
STP...
AC‑15 4 A 230 V /
DC‑13 4 A 24 V
STP...SR11
AC‑15 4 A 50 V /
DC‑13 4 A 24 V
Switching current, min., at
1 mA
24 V
Short circuit protection
(control circuit fuse) acc. to
4 A gG
IEC 60269‑1
Conventional thermal current
4 A
I
th
Solenoid operating voltage/solenoid power consumption
STP...024
AC/DC 24 V (+10%/‑15%) 8 W
STP...048
AC/DC 48 V (+10%/‑15%) 8 W
STP...110
AC
110 V (+10%/‑15%) 10 W
STP...230
AC
230 V (+10%/‑15%) 11 W
Duty cycle
100%
Locking force F
max
Straight actuator with bush
F
= 2,500 N
S
Bent actuator with bush
F
= 1,500 N
S
F
Locking force F
max
Zh
(F
=
Zh
acc. to EN ISO 14119
1.3
Switch with increased retention force STP.B..., STP.C...
Actuating force at 20 °C
45 N
Mechanical life, retention
1 x 10
operating cycles
5
Reliability values acc. to EN ISO 13849-1
B
5 x 10
6
10D
8
) = 2,000 N