Precision Multiple Limit Switches SN 12/16 mm
sealing of cable entry
f
loose cable connections or plug connectors.
f
Information: The year of manufacture can be seen
in the bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety instruc-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with plug connector:
For use and applications as per the requirements of
, a class 2 power supply according to UL1310
must be used. Connection cables for safety switches
installed at the place of use must be separated
from all moving and permanently installed cables
and un-insulated active elements of other parts
of the system which operate at a voltage of over
150 V. A constant clearance of 50.8 mm must be
maintained. This does not apply if the moving cables
are equipped with suitable insulation materials which
possess an identical or higher dielectric strength
compared to the other relevant parts of the system.
EC declaration of conformity
The manufacturer named below herewith declares
that the product fulfills the provisions of the direc-
tive(s) listed below and that the related standards
have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstr. 16
D-70771 Leinfelden-Echterdingen
Directives applied:
Machinery directive 2006/42/EC
f
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
f
EN 14119:2013
f
The original EC declaration of conformity can also
be found at: www.euchner.de
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
Fax:
+49 711 753316
E-mail:
support@euchner.de
Internet:
www.euchner.de
Technical data
Parameter
Housing material
Die-cast aluminum, anodized
Plunger material
Stainless steel
Degree of protection
IP 67
acc. to IEC 60529
Mech. operating cycles
ES502E/ES508E
ES514
Switching frequency
ES502E
ES508E/ES514
Ambient temperature
-5 ... +80°C
Installation position
Any
Max. approach speed
Plunger
Chisel D
40 m/min
Roller R (slide bearing) 80 m/min
Roller B (ball bearing)
120 m/min
Dome W/ball K
10 m/min
Min. approach speed
0.01 m/min
Actuating force
ES502E
with switching element
ES508E
ES514
Switching element
ES502E
1 NO contact + 1 NC contact
ES508E
1 positively driven NC contact
ES514
1 NO contact + 1 positively
driven NC contact
Switching principle
ES502E/ES514
Snap-action switch-
ing contact
ES508E
Slow-action switch-
ing contact
Hysteresis
ES502E
ES514
Contact material
ES502E/ES508E/ES514
Silver alloy, gold flashed
Connection
Screw terminals
Tightening torque of screw terminal
ES502E/ES508E/ES514
(cross-head screw)
0.5 Nm
Conductor cross-section
(rigid/flexible)
0.34 ... 1.5 mm
Rated insulation voltage
U
= 250 V
i
Rated impulse withstand voltage
ES508E/ES514
U
= 4 kV
imp
ES502E
U
= 2.5 kV
imp
Utilization category of switching element acc. to IEC 60947-5-1
ES502E
AC-12
250 V
ES502E/ES508E
AC-15
230 V
DC-13
24 V
ES514
AC-15
230 V 2.5 A
DC-13
24 V
Min. switching current
at DC 24 V
ES514
ES508E
at DC 12 V
ES502E
Conventional thermal current I
th
ES502E
8 A
ES508E/ES514
10 A
Short circuit protection acc. to IEC 60269-1 (control circuit fuse)
ES502E
8 A gG
ES508E
10 A gG
ES514
6 A gG
Conditional short-circuit current
100 A
Indicator LED
LE060
(only with ES502E/ES508E)
LE110
LE220
For design SN in LED version
with switching element ES514
and plunger spacing 12 mm
LE024GE
Reliability values according to EN ISO 13849-1
for switching elements
ES508E
B
2 x 10
7
10d
5
ES502E
Value
ES508E
30x10
6
1x10
6
300 min
-1
ES514
50 min
-1
Illustration: switching element not actuated
Figure 1: Switching elements and terminal assign-
ment
≥ 20 N
≥ 15 N
≥ 30 N
0.8 mm
0.6 mm
2
8 A
6 A
6 A
6 A
5 mA
10 mA
10 mA
AC/DC 12 - 60 V
AC 110 V ± 15%
AC 220 V ± 15%
DC 24 V ± 10%
ES514
2 x 10
6
22
21
14
13
22
21
22
21
14
13