TECHNICAL DETAILS
1.Installation (Fig 1)
Installation is the buyer's responsibility. The manufacturer accepts no liability for this service. Any action that
the manufacturer has to take due to an erroneous installation will not be covered by the guarantee.
The flush-mounted cook tops are designed for installation in work tops made of all kinds of material,
providing they can withstand a temperature of 100°C, and are between 25 and 40 mm thick.
of insulating material (wood or the like) must be inserted between the cook top and the space below. This partition
must be at least 10 mm from the underside of the cook top tray
Fixing the cook top to the unit (Fig 2)
The cook top is fixed to the unit by means of the brackets and accessories provided. Holes are provided in
the bottom of the tray where the tabs (A) are inserted so that you can attach the screws (C) that hold the
brackets (B) in place.
Applying the seal (Fig 3)
Important - The figure shows how the seal must be attached all around the perimeter.
This cook top has been designed for non-professional, domestic use.
2.Electric connections
Check the details given on the nameplate situated on the underside of the cook top, then make sure that the rated
mains voltage and power available are suitable for its operation.
Before making the electric connections, check the efficiency of the earthing system. Earthing of the cook top is
compulsory by law. The manufacturer will accept no liability for any personal injury or damage to property deriving
from failure to comply with this requirement.
For models without a plug, fit a standard plug capable of withstanding the specified load on the power cord. The
cord's earthing conductor is colored yellow and green. The plug must be accessible.
If you prefer to make a fixed connection to the mains, insert an all-pole circuit breaker with a breaking gap of at
least 3 mm between the cook top and the mains.
To connect the cook top power cord, loosen and remove the cover on the terminal block in order to access the
contacts inside. Make the connection, blocking the cord in place with the cable clamp provided and then close the
terminal block cover again immediately.
If you have to change the cord, the earthing (yellow / green) conductor must always be 10 mm longer than the line
conductors.
Use only rubber cable type H05RR-F.
DECLARATION OF CONFORMITY. In the parts destined to come into contact with foodstuffs, this appliance is in
accordance with the requirements of the EC directive 89/109 transposed in the Italian Legislative Decree N° 108 of
25/01/92.
CE Appliance conforming to the European directives 89/336/EEC, 93/68/EEC, 73/23/EEC and subsequent
revisions.
This appliance is marked according to the European directive 20002/96/EC on waste Electrical and electronic Equipment
(WEEE). This guideline is the frame of a europeanwide validity of return and recycling on Waste electrical and electronic
Equipment
MODELS
Voltage
Current
Hi light plate 1200 W
Hi light plate 1800 W
Max power W
Electrical cable
VITRO IX 302
230V
23,5 A
1
/
3000
2
3x1,5 mm
.
. A partition made