Preparation - Protector AS-5030 Mode D'emploi

Contrôleur pour extracteur d'air
Masquer les pouces Voir aussi pour AS-5030:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CODING THE EXHAUST AIR CONTROL

Preparation

Connect the sensor cable (K) to the furnace transmitter.
On the back of the furnace transmitter there are two screw
terminals, marked RED and BLACK. Loosen both screws and
slide the red cable lug of the thermos-sensor under the screw
marked RED and the other cable lug under the screw marked
BLACK. Tighten the screws again.
The window transmitter (6) and the furnace transmitter (9)
are not coded at the factory and must be taught in to the
receiver during the initial commissioning.
Please follow the order indicated precisely!
1. Insert the battery (CR 2477) in the window TRANSMIT-
TER (6). The LED on the transmitter lights up briefly.
2. Plug the connector of the device to be connected (e.g.
extractor hood) into the RECEIVER, and mount the
replugging safety device (S).
NOTE: The system cannot function without the replugging
safety device (S).
3. Then plug the RECEIVER into the network connector. The
LED „NETWORK" (3) lights up yellow if the function of
the RECEIVER is in order after the self-test.
4. At the RECEIVER keep the button (2) pressed down
for 2 seconds until the yellow LED „NETWORK" (3)
begins to flash.
5. Activate the window TRANSMITTER by holding the
magnet once on the housing (6a) and removing it
again. The LED integrated in the transmitter lights up. At
the RECEIVER the LED „Window" (4) lights up and the
teach-in process is completed.
6. Press the RECEIVER button (2) again for 2 seconds, the
yellow LED „NETWORK" (3) begins to flash.
7. Place the batteries (3x AAA) in the furnace TRANSMITTER
(9). The LEDs on the transmitter (12 and 13) light
up briefly.
8. Activate the FURANCE TRANSMITTER (9) by pressing
the Status button (11) once. The LEDs integrated in the
transmitter light up. The LED „Furnace" (5) lights up on
the RECEIVER and the teach-in process is completed.
You can set the current furnace status (hot or cold) by
pressing the Status button (11) on the furnace transmit-
ter (9). However, this is also automatically transmitted
during the next status change.
9. The TRANSMITTERS on the RECEIVER are now taught in
and the AS-5030.3 is ready for use.
TEACHING IN MULTIPLE TRANSMITTERS
1. Place a battery/the batteries in the TRANSMITTER
to be taught in.
2. Press the button (2) on the receiver for 2 seconds. The
LED „NETWORK" (3) begins to flash.
3. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing (6a) and removing it again
or pressing the Status button. The LED „NETWORK" (3)
stops flashing on the RECEIVER and the teach-in process
is completed.
4. Repeat steps 1), 2) and 3) for each
individual transmitter.
5. If 2 window transmitters and 2 furnace transmitters are
taught in, no further transmitters can be added.
15
ENGLISH | AS-5030

Publicité

Table des Matières
loading

Table des Matières