WARNING
Make sure the installation site you choose allows a minimum of 7 feet from the floor to the end of the
blades.
To reduce the risk of fire or electrical shock, do not use this fan with any solid state fan speed device or
variable speed control.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package
contents list and diagram. If any part is missing or damaged, do not attempt to assemble the product.
Contact customer service for replacement parts.
Estimated assembly time: 30 minutes to 1 hour.
Tools Required for Assembly (not included): Phillips screwdriver, flathead screwdriver, wire strippers,
electrical tape, ladder, safety glasses.
ASSEMBLY INSTRUCTIONS
WARNING-To reduce risk of fire, electric shock, or personal injury, mount to outlet box marked
"Acceptable for Fan Support of 15.9kg (35lbs) or less" and use mounting screws provided with the
outlet box and/or support directly from building structure. Most outlet boxes commonly used for
the support of luminaries are not acceptable for fan support and may need to be replaced.
Consult a qualified electrician if in doubt.
Warning-Risk of fire, electric shock, or personal injury. Ceiling fans may be either directly
supported from a structural framing member of a building and (see examples in figures A & B) or
may be mounted to an outlet box marked acceptable for fan support of 31.8 kg (70 lbs) to 15.9kg
(35 lbs) (see example in figure C).
A
B
4
C
Lowes.com/allenandroth