Mechanical Data
Ingress protection
Material
Mounting/ Installation
277896 / 6161622300
IP66 acc. IEC/EN 60529
Enclosure
Light dome
Wire guard
Fixing elements
Sealing ring
Special lock
Cable entries
Clamping range
Connection type
Terminal marking
Connection cross-
section
Protective con-
ductor connection
12/2021
Operating instructions CWB-ATEX
aluminium alloy copper-free, yel-
low/black powder-coated
polycarbonate, prismatic
stainless steel (accessory)
stainless steel
NBR-O-ring seal
Ex d enclosure; M4 hexagon socket
stud
1 x M20 x 1.5 stopping plug
1 x M20 x 1.5 cable gland
4 ... 13 mm
screw terminal block, 3-pole
L1 + N + PE
solid: 2 x 4 mm
fine stranded: 2 x 2,5 mm
inside: max. 6 mm
outside: max. 2,5 mm
rigid