GENERAL SETTINGS

14 : 14
BOILER
14 : 17
language
country
14 : 14
date
14 : 17
Time
Alarm tone
14 : 17
14 : 17
Water temp. & Programming
14 : 17
maintain /
Economy
temperature
Building type
programme
Timer schedule graphically programme the timer in 1 hour time blocks.
14 | nVent.com
GENERAL SETTING
SELECT LANGUAGE
SELECT COUNTRY
SELECT DATE
SELECT TIME
SELECT ALARM
SELECT SAVING TIME
choose your language from the language menu.
WATER TEMP. & PROGRAM
select a country in this menu. your selection defines
SELECT WATER TEMPRATURE
the default values used for time format, pipe diameter and
insulation thickness.
SELECT PROGRAM
PROGRAM TIMER
use the up/down arrow keys to select the year.
SELECT LANGUAGE
after a power break of more than 15 days you need to
re-enter the date.
SELECT COUNTRY
use up/down arrow keys to set hour and minute.
after a power break of more than 15 days you need to
SELECT DATE
re-enter the time.
SELECT TIME
An alarm will go off inside the unit indicating an error
condition. activate/deactivate the alarm by pressing on/
oFF. note: alarm messages and an alarm signal will be
SELECT ALARM
created any time in case of a malfunction.
SELECT SAVING TIME
SELECT WATER TEMPRATURE
SELECT PROGRAM
PROGRAM TIMER
The maintain temperature is the water temperature that
you set for normal use. the minimum temperature is 37°c
or the economy temperature, whichever is higher.
the maximum temperature depends on cable type, pipe
thickness, insulation thickness and ambient temperature.
the economy temperature is the water temperature for
periods in which the amount of hot water used is low (at
night) or high (peak period). select the temperature using
the + / - keys. the minimum temperature is 37°c in the
programme kindergarten and 41°C in the Apartments
programme. The maximum temperature is the selected
maintain temperature.
the Hwat-Eco has 7 default timer programmes. select by
tapping on the programme of choice (box will turn red).
see figure xx for the schedule of each programme.
the building programme reflects the tapping profiles.
you can set a block to oFF, Economy temp,
maintain temp, or HEAT-Up*
OFF
(*HEat-up=100% power, only when using the Hwat-r
cable. this is the legionella prevention mode and it is not
pre-programmed. Activate this preferably during night
hours to avoid scalding.
use the modes button to overwrite the timer schedule.
select a temperature mode to assign to the time bock of
choice.
14 : 17
ENGLISH
GERMANY
01.10.2017
14 : 17
OFF
ON
14 : 17
55 °C / 50°C
GENERAL SETTING
HOTEL
WATER TEMP. & PROGRAM
ECONOMY
MAINTAIN
14 : 17
ENGLISH
GERMANY
01.10.2017
14 : 17
OFF
ON
14 : 17
55 °C / 50°C
HOTEL
HEAT-UP