Pipe sensor
Pipe sensor
low
temperature
limit
Pipe sensor
high
temperature
limit
GENERAL SETTINGS
02:14 p.m.
BOILER
140 °F
14 : 17
Language
Country
Units of
14 : 17
Measure
Date
Time
Alarm
14 : 17
14 : 17
Water Temp. & Programming
14 : 17
Maintain /
Economy
temperature
Activate/deactivate a connected pipe sensor by pressing
ON/OFF. The pipe sensor monitors the pipe temperature
and needs to be installed close to the furthest point in the
pipe distribution network.
You can determine the low temperature limit.
When the value is reached a warning will appear on the
screen but will not interrupt the unit's functioning. The info
status screen will show the actual pipe temperature.
You can determine the high temperature limit. A warning
will appear on the screen when the value is reached but
will not interrupt the unit's functioning.
GENERAL SETTING
SELECT LANGUAGE
SELECT COUNTRY
SELECT DATE
SELECT TIME
SELECT ALARM
SELECT SAVING TIME
Choose your language from the language menu.
WATER TEMP. & PROGRAM
Select a country in this menu. Your selection defines
SELECT WATER TEMPERATURE
the default values used for time format, pipe diameter
SELECT PROGRAM
and insulation thickness.
PROGRAM TIMER
Choose your desired units of measure Metric (mm, °C) or
Imperial (in, °F)
Use the up/down arrow keys to select the year.
SELECT LANGUAGE
After a power break of more than 10 days you need to
re-enter the date.
SELECT COUNTRY
Use up/down arrow keys to set hour and minute.
After a power break of more than 10 days you need to
SELECT DATE
re-enter the time.
SELECT TIME
An alarm will go off inside the unit indicating an error
condition. Activate/deactivate the alarm by pressing ON/
OFF. Note: Alarm messages and an alarm signal will be
SELECT ALARM
created any time in case of a malfunction.
SELECT SAVING TIME
SELECT WATER TEMPERATURE
SELECT PROGRAM
PROGRAM TIMER
The maintain temperature is the water temperature that
you set for normal use. The minimum temperature is
98°F/37°C or the economy temperature, whichever is
higher. The maximum temperature depends on cable type,
pipe thickness, insulation thickness and ambient
temperature. The economy temperature is the water
temperature for periods in which the amount of hot water
used is low (at night) or high (peak period). Select the
temperature using the + / - keys. The minimum
temperature is 98°F/37°C for use in environments such as
schools, and 105°F/41°C in the Apartments program.
The maximum temperature is the selected maintain
temperature.
14 : 17
ENGLISH
UNITED STATES
01.10.2017
14 : 17
OFF
ON
14 : 17
131°F/122°F
HOTEL
GENERAL SETTING
WATER TEMP. & PROGRAM
14 : 17
ENGLISH
UNITED STATES
01.10.2017
14 : 17
OFF
ON
14 : 17
131°F/122°F
HOTEL
nVent.com | 15