Safety Edge Wiring - SOMFY Rollixo Smart io Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rollixo Smart io
WARNING
The earth wire must always be longer than the live and neutral to ensure that it is the last to be disconnec-
ted if the connector is pulled out.
The cable clamp supplied must be used.
For all low-voltage cables, ensure that they can withstand traction of 100 N. Check that the conductors do
not move when this traction is applied.
3.5

Safety edge wiring

DANGER
Wiring a safety edge is compulsory.
The operation must be carried out with the power off.
3.5.1
Connect the safety edge
Optical wired safety edge
> > > Illustration 8
Translation of the colours present on the safety edge wiring diagram:
EN
EN
Brown
Brown
Green
Green
White
White
Wired resistive safety edge 1.2 kΩ or 8.2 kΩ.
> > > Illustration 9
3.5.2
Adjust setting P2 according to the type of safety edge connected
1] Press the "SET" button for 0.5 s to enter parameter setting mode.
ð Indicator light P0 flashes once.
2] Press the "SET" button twice to move on to parameter P2.
ð Indicator light P2 flashes once to indicate the value selected.
3] Press the "+" or "-" button to change the value of the parameter.
ð The indicator light flashes x times to indicate the value selected.
• P2 = 1 x: Optical wired safety edge
• P2 = 2 x: Resistive wired safety edge 1.2 kΩ
• P2 = 3 x: Resistive wired safety edge 8.2 kΩ
4] Press the "SET" button for 2 s to confirm a value and exit parameter setting mode.
ð The parameter setting indicator lights go out.
©
Copyright
2020 SOMFY ACTIVITES SA. All rights reserved.
EN
33

Publicité

Table des Matières
loading

Table des Matières