EN
1.5
Electrical installation
DANGER
The installation of the power supply must comply with the standards in
force in the country in which the motorisation is installed, and must be
carried out by qualified personnel.
The electric line must be exclusively reserved for the motorisation and
equipped with protection, comprising:
a 10 A fuse or breaker,
a differential type device (30 mA).
An all-pole power supply cut-off device must be provided. The switches
provided to ensure a cut-out of all poles on fixed appliances must be con-
nected to the power supply terminals and there must be a separation
between the contacts on all poles to ensure complete disconnection in
conditions where category III high impulse voltage is present.
Low-voltage cables subject to inclement weather must be at least of type
H07RN-F.
It is recommended that you fit a lightning conductor (mandatory max-
imum residual voltage 2 kV).
Cable run
Underground cables must be equipped with a protective sheath with a sufficient
diameter to contain the motor cable and the accessories cables.
For overground cables, use a cable grommet that will withstand the weight of
vehicles.
1.6
Safety instructions relating to installation
DANGER
Do not connect the motorisation to a power source before installation is
complete.
WARNING
Modifying any of the components in this kit or using additional compon-
ents not recommended in this manual is strictly prohibited.
Monitor the door as it moves and keep people away from it until installation is
complete.
Do not use adhesive to mount the motorisation.
CAUTION
Install any fixed control device at a height of less than 1.5 m and within
sight of the door, but away from moving parts.
After installation, ensure that:
• the motorisation changes direction when the door encounters an object 50 mm
high on the ground.
Clothing precautions
Take off any jewellery (bracelet, chain, etc.) during installation.
28
©
Copyright
2020 SOMFY ACTIVITES SA. All rights reserved.