Trouble
Ineffective display
12. PRODUCT MARKING
All of the indicators and labels placed on the product by the manufacturer must be kept clearly readable.
Should they be lost or damaged, replace these indicators and labels before continuing to use the
appliance. Tractel
can provide new labelling on request.
®
Possible causes
Dead sensor batteries
Sensor switched off or
switched to take standby
mode.
Sensor too far from display
unit.
Network conflict
Sensor subject to compression
or torsion.
Negative imbalance of gauge
bridge.
Switch on a Master display unit
on a site where several LLX1
are already operating.
Malfunction of the display.
Marking display
23
Solutions
Replace batteries.
Switch off display unit, switch
on sensor, switch on display
unit.
Bring appliances closer
together.
Check network configuration
Eliminate compression stress
on sensor.
Contact the after-sales service.
Select a other channel
(see § 7).
Keep the ON/OFF key pressed
during 10 sec.
Reboot both load cell and
display.
Marking battery
charger
.
GB