The fixtures, electrical cables, flexible pipes and water connections under the bathtub must be as long as needed,
so that they will not be damaged if the bathtub is lifted! The warranty does not cover damages relating to any such
insufficiencies!
Ensure proper ventilation and access to the vents when installing the hydro massage bathtub! The vent must be at
least 100 cm2! The warranty does not cover damages relating to improper ventilation!
Level installation and the proper set up of the level-stand is mandatory. Contact a qualified professional for help. If
the level-stand is not set up properly, tension in the body of the bathtub may lead to the cracks in the acrylic body.
Before operating the bathtub see if the conditions of operation are suitable and check for leakage.
When setting up drainage fixtures you must inspect the return air flow guard.
If your bathtub has any glass panels, you must take extra care when transporting or moving the product. It is express-
ly forbidden to push, lift by, or otherwise put load on the glass panels. These actions may lead to leakage.
If your bathtub has any handles, towel bars, or pillow holders, you must take extra care when transporting or moving
the product. It is expressly forbidden to push, lift by, or otherwise put load on these accessories. These actions may
lead to the straining, deformation, or breakage of the acrylic device.
The supporting structure under the bathtub's flanges must be used to lift and move the bathtub.
The warranty does not cover breakdowns due to improper installation.

Bathtub feet

The leveling feet are not load-bearing!
You are therefore required to construct a proper support for those!
Hydromassage bathtubs can only be ordered with feet which are in themselves load-bearing! When installing the
bathtub, every foot must be adjusted to stand on the floor. Failure to do so may result in cracking of the bathtub
body, which the manufacturer cannot be liable for!
The bathtub must be leveled by adjusting the bathtub feet!

Acrylic front panel installation procedure

The hydro massage bathtub's stand must be set up so as to leave a 1 cm wide gap between the front panel and the
floor! This ensures the engine's proper ventilation!
You may install a commercially available drainage profile between the wall and the bathtub's flange to prevent water
dripping off of wall surfaces pooling behind/under the bathtub.

Installing water-, drainage-, electrical fixtures

1. Water fixture installation (optional faucet)
Faucets must be installed at the points marked on the connection diagram, using ½" angle valves!
2. Drainage fixtures
The diameter of the connection for the flexible drainage pipe is 40 mm!
The point marked on the connection diagram represents the exact drainage fixture! Its location is in accordance
with the support, we do not recommend deviating from it!
3. Electrical fixtures
Only qualified professionals may carry out the installation of bathtubs with electrical fixtures. Installation must
be carried out in accordance with safety regulations.
A 3 meters long, 3 x 2,5 mm thick MTK cable must be installed behind the bathtub's body, at least 300 mm above
the floor!
An equipotential bonding grid (EPH) must be installed in the vicinity of the device!
Using a plug for the electrical connection is expressly forbidden!
You can find the exact locations of the fixtures on the attached connection diagram!