5. The metal flange under each side of
the cooktop MUST be placed over
the cabinet countertop for proper
unit support. The cooktop should
NOT rest directly on the countertop
or else it could cause damage to
the cooktop voiding the warranty.
Level the unit if needed.
IMPORTANT: MAKE SURE the unit is supported by the leveling legs and NOT by
gAS REQUIREMENTS
Provide adequate gas supply
This range is designed to operate at a pressure of 5 in (13 cm) of water column
on natural gas or 10 in (25 cm) of water column on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is designed.
Do not attempt to convert the appliance from the gas specified in this manual
to a different gas without consulting the gas supplier.
This range is convertible for use on natural or propane gas. If you decide to use this
range on LP gas, conversion must be made by a qualified LP installer before attempting
to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator must be
between 5 in and 13 in (13 cm and 33 cm) of water column.
For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and 33 cm)
of water column.
When checking for proper operation of the regulator, the inlet pressure must be at least
1 in (2.5 cm) greater than the operating (manifold) pressure as given.
The pressure regulator located at the inlet of the range manifold must remain in the
supply line regardless of whether natural or LP gas is being used.
A flexible-metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal tubing when moving the range.
the cooktop itself.