Ducting Options

Closely follow the instructions set out in this manual.
All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.
The hood is equipped with a 8" (20.3 cm) round transition for discharge of fumes to the outside.
Typical Internal Blower Motor System Venting Installations
Roof Venting
A
B
A.
Roof cap
B.
8" (20.3 cm cm) round vent
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist
or stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types
of walls/ceilings.
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Recommended installation height:
I CAUTION
For gas cooktop & range installations: Mount the hood so the
bottom is at least 3O" (76.2 cm) above the cooking surface.
6
Ducting options
Wall Venting
B
A
A.
Wall cap
B.
8" (20.3 cm cm) round vent
Typical In-line Blower Motor System Venting Installations
C
D
A
B
A
A.
8" (20.3 cm) round vent
B.
Mount on top of ceiling
joists.
C.
Roof caps
D.
Plywood (optional for some
installations)
For electric/induction cooktop & range installations: Mount
the hood so the bottom is at least 24" (61 cm) above the
cooking surface.
There is no maximum mounting height, however, we recom-
mend mounting the hood no greater than 36" (91.4 cm) above
the cooking surface. For every inch (2.54 cm) above 36" (91.4
cm), fume and moisture capture efficiency diminishes at an
increasing rate and may not deliver an acceptable level of
ventilating performance.
This hood is intended for household use.
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC
APPLICATION. Check your ceiling height and hood height
before selecting your hood.
A
E
D
A
F
G
H
E.
Mount on underside of roof
rafters.
F.
Mount from cross-members
tied to trusses.
G.
Duct horizontal; mount to
cross-members tied to trusses.
H.
Wall cap