Ducting Options

Closely follow the instructions set out in this manual�
All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined�

Ducting version

This range hood is factory set for venting through the roof
or through the wall� The vent system needed for installation
is not included�
A 6" (15�2 cm) round vent system is recommended�
Roof Venting
B
A
A. 6" (15.2 cm) vent through the roof
B. B.
Roof cap
Preparation
Fittings material is provided to secure the hood to most types
of walls/ceilings�
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling�
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent�
Wall Venting
A
B
A. 6" (15.2 cm) vent through the wall
B. B.
Wall cap

Ductless (Recirculating)

In cases where it should not
be possible to discharge
cooking fumes and vapour to
the outside�
You can apply the
recirculating venting
method by purchasing the
Recirculation Kit�
I CAUTION
For gas cooktop & range installations: Mount the hood so the
bottom is at least 30"(76�2 cm) above the cooking surface�
For electric/induction cooktop & range installations: Mount
the hood so the bottom is at least 24" (61 cm) above the
cooking surface�
There is no maximum mounting height, however, we
recommend mounting the hood no greater than 36" (91�4
cm) above the cooking surface� For every inch (2�54 cm)
above 36" (91�4 cm), fume and moisture capture efficiency
diminishes at an increasing rate and may not deliver an
acceptable level of ventilating performance�
This hood is intended for household use�
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC
APPLICATION� Check your ceiling height and hood height
before selecting your hood�
A
B
A. 6" (15.2 cm) vent through the cabinet
B. B.
Round recirculating grid
7