Detection Method - RISCO Group LuNAR DT AM Grade 3 Guide D'installation

Masquer les pouces Voir aussi pour LuNAR DT AM Grade 3:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 74
Remote Control and Diagnostic Features
Remote microwave adjustment enables one-man walk test.
Diagnostic tools include detector input voltage reading and status of each PIR channel and
MW channel (signal voltage and noise levels), AM channel (signal voltage), SW version
verification.
Remote display and control of detector settings: MW adjustment, ACT on/off, LEDs on/off.
Remote trouble indication (Pass/Fail) for the PIR, MW and power supply input
Control of MW bypass (during MW trouble) and MW disable during Disarm ("Green Line")
when connected to ProSYS.
*Via the optional Bi-Directional Infrared Remote Control, or the ProSYS Upload/Download
Software and Keypad.

Detection Method

The Industrial LuNAR DT AM Grade 3 detection is based on:
PIR (Passive Infra-Red) - which responds to changes in the IR radiation caused when an
intruder crosses the protected area.
MW (Microwave) - which transmits signals and analyzes the frequency changes of the
reflected echo from an intruder using Doppler Effect.
ALARM is initiated only when both technologies trigger simultaneously (except for certain situations in
the ACT mode-see page 4 – "How ACT™ Works"), thus greatly reducing the possibility of false alarms.
Industrial LuNAR DT AM Grade 3 Installation Guide
*
3

Publicité

Table des Matières
loading

Table des Matières