RISCO Group LuNAR DT AM Grade 3 Guide D'installation page 20

Masquer les pouces Voir aussi pour LuNAR DT AM Grade 3:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 74
BUS Mode Configuration (DIP
switch 6=ON):
DIP
Description
switch
Number
Used to set the detector ID number. (See Table 1)
1-5
Set the ID number in the same way as for any other ProSYS accessory.
Used to determine the detector's connection mode.
6
DIP switch ON: ProSYS connection – BUS configuration
NOTE:
Upon power up or normal operation, the LuNAR waits 10 seconds for ProSYS communication.
Communication problem may occur due to bad wiring, wrong address, or ProSYS not configured
properly; RED LEDs will continuously flash until the problem is solved.
Not applicable (RC
7
the ProSYS and disabled otherwise).
8-9
DIP Switch ON: in order to enable the detector to report the tamper status to ProSYS.
ID
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
18
communication
Table 1: ID Settings for BUS connection
1
2
3
4
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
Industrial LuNAR DT AM Grade 3 Installation Guide
BUS ADDRESS
ON
1
2
3
4
is automatically enabled when entering Walk Test mode in
5
ID
1
17
OFF
OFF
18
OFF
ON
19
OFF
OFF
20
OFF
ON
21
OFF
OFF
22
OFF
ON
23
OFF
OFF
24
OFF
ON
25
OFF
OFF
26
OFF
ON
27
OFF
OFF
28
OFF
ON
29
OFF
OFF
30
OFF
ON
31
OFF
OFF
32
OFF
ON
TAMPER
BUS
N/A
MODE
8
9
5
6
7
2
3
4
5
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON

Publicité

Table des Matières
loading

Table des Matières