DDLI-25/32/40/63
For control of the DDLI:
• Use proportional directional control valve MPYE or VPWP for
speed control and positioning (example of circuit
circuit is not suitable for stopping the slide in the event of a
pressure failure.
If used as a measuring cylinder:
• Use the one-way flow control valves GRLA for setting the speed
and, in addition, external stops.
5.3
Installation, electric
• Wire the DDLI to the earth potential.
The internal thread (A) of the cover screws can be used for this
purpose, for example (
• Wire the measuring system connection 1 to the control system.
Only the existing cable may be used for this purpose.
Size
Female thread (A) of the cover screws
Max. tightening torque
Tab. 5
Pin allocation DDLI:
Pin
Function
1
24 V DC
2
n. c.
3
0 V
4
CAN_H
5
CAN_L
–
Screening
Tab. 6
Festo – DDLI-25/32/40/63 – 1402a English
Tab. 5).
[Nm]
Fig. 8). This
Fig. 8
(A)
Fig. 9
25
32
M4
M5
3.0
4.0
Pin allocation
5 ìm
1
40
63
M5
M8
5.0
14
27