5.2.10. General information
Mechanical
Dimensions :
Weight (inc. battery) :
Casing and circuit :
Packaging
Dimensions :
Weight :
Power supply
Power requirements :
Low battery indication :
Battery life :
Display
Liquid crystal display comprising :
- a 50 000-count display + sign (digits 11 mm high)
- a 34-bar analogue bargraph display
- appropriate units for each type of measurement
- triggered mode indicators (storage, ranging, ...)
- battery discharged indicator
Measurement rate
Digital display :
Bargraph :
5.2.11. Environment
Reference temperature :
Limit range of operation :
Rated range of use :
Storage temperature range :
Temperature coefficient :
Relative humidity :
Water-tightness :
Max. influence in electro-magnetic fields at
3 V/m acc. to EN 61000-4-3, 1995 :
5.2.12. EMC
This apparatus was designed in accordance with the EMC standards in force and its
compatibility has been tested in accordance with the following standard :
• Emission and Immunity EN 61326 + A1, 1998
The product conforms to the prescriptions of the European directive low voltage directive
73/23/EEC and the EMC directive 89/336/EEC, amended by 93/68/EEC.
26
• additional error in Ω :
• frequency sensitivity :
170 x 80 x 35 mm
285 g
self-extinguishing materials
230 x 155 x 65 mm
385 g
single 9 V alkaline battery (6LF22)
BAT is displayed when the battery
voltage drops below operating voltage
500 hours approx. in V
2 measurements/s
20 measurements/s
23°C ± 5°C
-5°C to 45°C
-10°C to 55°C
-20°C to 70°C
max. 0.1 x (accuracy) / K
50 D from -5°C to 0°C
max. 0.3 x (sensitivity) / K
0 to 80 % from 0 to 35°C
(70 % max. for 5 / 50 MΩ)
0 to 70 % from 35°C to 50°C
IP 50
± 150 D in 10 A
± 50 D in mA
± 3 % in all other ranges
5000-count portable digital multimeter, with current input
Chapter II
mode
DC
range
AC+DC
range
AC+DC