WAGNER CONTROL SPRAY MAX Manuel De L'utilisateur page 8

Masquer les pouces Voir aussi pour CONTROL SPRAY MAX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance
Before you begin:
You should inspect the air filters in the turbine
to see if they are excessively dirty. If they are
dirty, follow these steps to replace them.
impoRtAnt: never operate your unit
without the air filters. Dirt could be sucked
in and interfere with the function of the
unit.
Troubleshooting
Problem A: Little or no material flow
Cause
1.
Nozzle clogged.
2.
Suction tube clogged.
3.
Material volume setting turned too low (-).
4.
Suction tube loose.
5.
No pressure build up in container.
6.
Air filter clogged.
Problem B: Material leaking
Cause
1.
Nozzle loose.
2.
Nozzle worn.
3.
Nozzle seal worn.
4.
Material build-up on air cap and nozzle
English
All manuals and user guides at all-guides.com
1
1. Press the tabs (a) on each side of the turbine to
remove the filter covers.
Solution
Clean.
Clean.
Increase volume setting (+).
Insert.
Tighten container.
Change.
Solution
Tighten.
Replace.
Replace.
Clean.
8
2
2. Remove the dirty filters from the turbine and
replace with new ones. The smooth side of the
air filter must be placed toward the turbine.
Secure the covers back onto the turbine.

Publicité