WAGNER CONTROL SPRAY MAX Manuel De L'utilisateur page 7

Masquer les pouces Voir aussi pour CONTROL SPRAY MAX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleanup
Before you begin:
When cleaning, use the appropriate
cleaning solution (warm, soapy water for
latex materials; mineral spirits for oil-based
materials)
special cleanup instructions for
use with flammable solvents
(must have a flashpoint above
70ºF (21ºC):
• Always flush spray gun outside.
• Area must be free of flammable vapors.
• Cleaning area must be well-ventilated.
• Do not submerge turbine!
5
5. Spray the solution through the gun
for two seconds in a safe area.
Spray again for two seconds. Turn
off the turbine, and trigger the spray
gun so that the material inside
the spray gun flows back into the
container. Wipe the exterior of the
cup and gun until clean.
All manuals and user guides at all-guides.com
1
1. Turn the turbine OFF.
Trigger the spray gun so
that the material inside
the spray gun flows
back into the container.
6
7
7. Clean the container, suction tube,
air cap and nozzle with a cleaning
brush and the appropriate
6. Unscrew the nut and
cleaning solution.
remove the air cap and
nozzle.
impoRtAnt: never clean nozzle
or air holes in the spray gun with
sharp metal objects. Do not use
solvents or lubricants containing
silicone.
2
3
3. Pour a small amount of
the appropriate cleaning
solution into the cup.
Clean cup and suction
2. Unscrew the container.
tube and properly dispose
Empty any remaining
of cleaning solution. Refill
material back into the
the cup with nEW cleaning
material container.
solution.
8
8. Push the tab below
the trigger, twist and
separate the spray gun
from the handle.
7
4
4. Attach the cup to the
gun and turn on the
turbine.
9
(a)
(b)
9. Clean the rear of the spray
gun (a) with the appropriate
cleaning solution. Use a
thin layer of petroleum jelly
to lubricate the O-ring (b).
Reassemble spray gun.
English
English

Publicité

Table des Matières
loading

Table des Matières