6
Troubleshooting
6.1
Troubleshooting
Error
|Battery error|
|Motor error|
|Flap error|
|max. flap operating
cycles|
Pot-free contact
does not switch
52 / 164
Cause
Battery is missing, is defective or voltage is
too low
Cable break or motor faulty
Flap cannot be closed completely, i.e. the
flap is blocked by an object
Backwater has been detected and the flap
cannot be closed completely, i.e. the flap is
blocked by an object
max. number of flap cycles exceeded
not activated or the miniature fuse is defec-
tive
Remedial measures
Check the battery connection, replace bat-
tery if necessary
Disconnect the system from the mains
power supply, disable the battery, check the
cable for correct connection and continuity;
test the function of the motor, replace if nec-
essary
Pull out the mains plug, disconnect the bat-
tery, open the flap cover and remove the
blockage and restart the system
Close the emergency closure (hinged flap,
if present). Following the end of backwater,
eliminate the blockage as described above.
To install the flap cover, the flap motor must
be in the CLOSED position.
Replace motor, motor life reached
Get a qualified electrician to activate/check.
016-003