4.3
Connect the plug to the underside of the control unit
NOTICE
Disconnect system from energy sources!
Ensure that the electrical components are dis-
connected from the electrical power supply dur-
ing the work.
Shorten and/or lengthen cable with plug to fit. To lengthen
(max. 30m), only use the suitable cable extension set
(art. no. 80889, 80890, 80891). To shorten, proceed as
follows:
Lay cable up to connection, measure 5 cm reserve.
Cut off using combination pliers. Strip cable jacket
from approx. 3 cm before the end of the cable.
Pull the nut off the cable cutoff and push onto the
exposed wires.
Bend over the wires into the recesses in the side,
then cut off flush.
The remaining installation does not require any tools.
Connecting the (backwater flap) motor
Remove nut (connector) and protective cap.
Align cable arrow on arrow and push on.
38 / 164