Commissioning
Danger! High voltage: this symbol warns of high
voltages which may result in injuries to persons
and/or damage to equipment. Where appropriate,
the text printed adjacent to this symbol describes
how risk of this kind may be avoided.
General warning: this symbol warns of non-elec-
trical risks and dangers which may result in serious
or even fatal injuries to persons and/or damage to
equipment. Where appropriate, the text printed
adjacent to this symbol describes how risk of this
kind may be avoided.
Warning of electrostatic discharge: this symbol
warns you against electrostatic discharges which
may damage to unit. Where appropriate, the text
printed adjacent to this symbol describes how risk
of this kind may be avoided.
NEC motor overload protection
The DCS800 provides a solid-state motor overload
protection in accordance with the NEC. The overload
protection (e.g. protection level in percent of full-load
motor current) can be adjusted by parameters in
group 31 and group 99.
The instructions can be found in chapter Motor
thermal model of the DCS800 Firmware manual.
Commissioning DriveWindow Light
Start the wizard in DriveWin-
dow Light:
For basic commissioning press the Start button or select a specific assistant:
Select specific
assistant & press Next
For more information about the wizard, parameters faults and alarms press the Help
button!
General instructions
• This short commissioning refers to Chapter 5 Con-
nection examples of this publication.
• Safety and operating instructions - see chapter 6
of this publication.
• Recommendations for motor and field voltages see
Technical catalogue.
• In accordance with DIN 57 100 Part 77 / VDE 0100
Part 77, precautions must be taken to enable the
drive to be shut down, e.g. in the event of danger.
The unit's digital inputs or the control panel are not
sufficient as the sole measure for this purpose!
Preparations
• Check unit for any damage!
• Install unit and wire it up
• Supply voltage level / Rated value correct for elec-
tronics and fan?
• Supply voltage level / Rated value correct for arma-
ture-circuit converter?
• Supply voltage level / Rated value correct for field
supply?
• Wiring / cross-sections, etc. correct?
• EMERGENCY STOP functioning properly?
• COAST STOP functioning properly?
7. Field weakening assistant
6. Autotuning speed controller
5. Speed feedback assistant
4. Autotuning armature current controller
3. Autotuning field current controller
2. Macro assistant
1. Name plate data
3ADW000191R0500 DCS800 Quick guide edisf e
Next >
Next >
Next >
Next >
Next >
Next >
Wiz select.dsf
19