Commissioning

Danger! High voltage: this symbol warns of high
voltages which may result in injuries to persons
and/or damage to equipment. Where appropriate,
the text printed adjacent to this symbol describes
how risk of this kind may be avoided
General warning: this symbol warns of non-elec-
trical risks and dangers which may result in
serious or even fatal injuries to persons and/or
damage to equipment. Where appropriate, the text
printed adjacent to this symbol describes how risk
of this kind may be avoided.
Warning of electrostatic discharge: this symbol
warns you against electrostatic discharges which
may damage to unit. Where appropriate, the text
printed adjacent to this symbol describes how risk
of this kind may be avoided.
NEC motor overload protection
The DCS550 provides a solid-state motor overload protection
in accordance with the NEC. The overload protection (e.g.
protection level in percent of full-load motor current) can be
adjusted by parameters in group 31 and group 99
The instructions can be found in chapter Motor thermal model
of the DCS550 Manual.
Commissioning DriveWindow Light
Start the wizard in
DriveWindow Light
For basic commissioning press the Start button or select a specific assistant:
Select specific
Select specific
assistant & press Next
assistant & press Next
For more information about the wizard, parameters faults and alarms press the Help button!

General instructions

− This short commissioning refers to chapter Connection
examples of this publication.
− Safety and operating instructions - chapter of this publica-
tion.
− Recommendations for motor and field voltages see Techni-
cal catalog.
− In accordance with DIN 57 100 Part 727 / VDE 0100 Part
727, precautions must be taken to enable the drive to be
shut down, e.g. in the event of danger. The unit's digital
inputs or the control panel are not sufficient as the sole
measure for this purpose!
Preparations
− Check unit for any damage!
− Install unit and wire it up
− Supply voltage level / Rated value correct for electronics
and fan?
− Supply voltage level / Rated value correct for armature-
circuit converter?
− Supply voltage level / Rated value correct for field supply?
− Wiring / cross-sections, etc. correct?
− EMERGENCY STOP functioning properly?
− COAST STOP functioning properly?
7. Field weakening assistant
7. Field weakening assistant
6. Autotuning speed controller
6. Autotuning speed controller
5. Speed feedback assistant
5. Speed feedback assistant
4. Autotuning armature current controller
4. Autotuning armature current controller
3. Autotuning field current controller
3. Autotuning field current controller
2. Macro assistant
2. Macro assistant
1. Name plate data
1. Name plate data
3ADW000395R0100 DCS550 Quick guide edisf a
3ADW000395R0100 DCS550 Quick guide edisf a