Function
Parameter Description
Min heating water
temperature
Max heating water
temperature
Max outdoor air
temperature in cooling
mode
Min outdoor air
temperature in cooling
mode
Min cooling water
56
temperature
Max cooling water
temperature
Outdoor air temp.
sensor GMC
TO sensor value
TE sensor value
TS sensor value
TD sensor value
Operating mode
Compressor max
frequency
Requested frequency
Actual frequency
Compressor run time
Capacity
EWT sensor value
LWT sensor value
TR sensor value
Operating mode
Errors
Gmc software version
Gmc software version
Water pump run time
Current water set
point
Clean contact off
Alarm/ ambient air
temperature reached
All manuals and user guides at all-guides.com
120
Code used to select the minimum outdoor temperature of the heating climate curve. 20°C
121
Code used to select the maximum outdoor temperature of the heating climate curve. 20°C
Code used to select the maximum outdoor temperature of the cooling climate curve,
122
which depends on the country where the system is installed.
Code used to select the minimum outdoor temperature of the climate curve in
123
cooling mode
Code used to select the minimum water temperature of the climate curve in cooling
124
mode.
Code used to select the maximum water temperature of the climate curve in cooling
125
mode.
Code used to indicate whether the GMC outdoor air temperature sensor is installed
or not
126
1. GMC external air temperature sensor installed
2. GMC external air temperature sensor not installed
127
The code indicates the outdoor air temperature value measured by the TO sensor
128
The code indicates the refrigerant temperature value measured by the TE sensor
129
The code indicates the refrigerant temperature value measured by the TS sensor
130
The code indicates the refrigerant temperature value measured by the TD sensor
The code indicates the current operating mode of the Heat Pump
1. Off
2. Cooling
131
3. Heating
4. Faulty
5. Defrost
The code indicates the maximum frequency of the compressor calculated by the
132
GMC control board
133
The code indicates the frequency requested by the system control
134
The code indicates the actual compressor frequency
135
The code indicates the compressor working hours
136
The code indicates the nominal capacity of the heat pump (kW)
137
N.A.
The code indicates the temperature of the water leaving the heat pump read by the
138
LWT sensor
139
The code indicates the temperature of the refrigerant measured by the TR sensor
The code indicates the operating mode requested by the System Control
0. Off
1. Stand by
2. Cooling
3. Heating
4. N.A.
5. N.A.
140
6. Nominal Heating
7. Nominal cooling
8. Antifreeze protection
9. Defrost
10. High temperature protection
11. Compressor start waiting
12. System error
13. Advanced freeze protection
The code lists all the error codes detected by the outdoor unit. If there are no errors,
141
no code is displayed.
142
The code indicates the GMC software release
143
The code indicates the GMC Software Version
144
The code indicates how long the water pump has been operating.
145
The code indicates the current water set point set by the system control.
Code used to set the various SWITCHING OFF logics
146
1. Standard OFF
2. Controlled OFF cycle (only if the Heat Pump is controlled by clean contact)
Code used to select the output connected to PIN 5 of the terminal board
147
1. Alarm signal
2. Signal that the air temperature set point has been reached
HYDRONIC UNIT LE B
Value range
Min
24°C
0°C
4°C
4°C
Default
Set
value
value
Max
60°C
35°C
60°C
55°C
46°C
40°C
30°C
20°C
20°C
4°C
20°C
15°C
1
2
2
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
-
-
-
Lock
1
2
1
1
2