ADJUSTMENT OF THE CIRCULATION PUMP
Model 4 B - 6 B - 8 B
The circulation pump features a knob for adjusting the head
in 2 operating modes with 8 positions each.
The factory setting is in Mode with constant pressure
differential in position 8.
The deaeration function is activated after 3 seconds with a
duration of at least 10 minutes.
For any change in the factory settings please contact
BERETTA Technical Service.
Mode with variable pressure differential
Deaeration function
Mode with constant pressure differential
Modello 12 B
The circulation pump features an interface that allows the
head to be adjusted in 6 levels and 2 operating modes.
The factory setting is CP3.
For any change in the factory settings please contact
BERETTA Technical Service.
Fast blinking
1
Slow blinking
2
Factory setting
CP3
All manuals and user guides at all-guides.com
1
PP1
PP2
PP3
RÉGLAGE DE LA POMPE DE CIRCULATION
Modèle 4 B - 6 B - 8 B
La pompe de circulation est équipée d'un bouton de réglage
de la hauteur de refoulement sur 2 modes de fonctionnement
avec 8 positions pour chacun.
Le réglage d'usine est en mode avec différentiel de
pression constante en position 8.
La fonction de désaération s'active après 3 secondes
pendant une durée d'au moins 10 minutes.
En cas de modification des réglages d'usine, contacter le
Service Technique d'Assistance BERETTA.
Mode avec différentiel de pression variable
Fonction de désaération
Mode avec différentiel de pression constante
8
Modèle 012 B
La pompe de circulation est équipée d'une interface qui
permet de régler la hauteur de refoulement sur 6 niveaux et 2
modes de fonctionnement.
Le réglage d'usine est CP3.
En cas de modification des réglages d'usine, contacter le
Service Technique d'Assistance BERETTA.
Clignotement rapide
1
Clignotement lent
2
Réglage d'usine
CP3
2
CP1
CP2
CP3