TABLE OF FUNCTIONS AND USER PARAMETERS
Function
Mode
Home antifreeze
52
Ambient antifreeze
temperature
Set point adjustment
frequency reduction mode 5
Frequency reduction
Room mode
Room control set point
Room set point
Relative humidity value
from the sensor
Outdoor temperature
Outdoor temperature -
GMC
Room sensor temperature
adjustment
Day period
"At home" temperature in
heating mode
"At home" temperature in
cooling mode
"Night" temperature in
heating mode
"Night" temperature in
cooling mode
"Away from Home"
temperature in heating
mode
"Away from Home"
temperature in cooling
mode
Room set point
Last alarm code
Alarms log
In case of parameters which are read-only and cannot be edited by user, key pad lock ( Lock) icon is displayed on the screen.
The list of Read-only parameters is given below: 7, 8, 9, 10, 11, 12, 21, 22 and 23
All manuals and user guides at all-guides.com
Parameter
Description
1
This parameter allows you to select the mode
0. Off
2. Cooling
3. Heating
2
This parameter enables the ambient antifreeze option when the system
is off:
1. NO. Disabled
2. YES. Enabled
3
This code allows you to select the temperature threshold below which
the ambient (0/+ 2 °C hysteresis) antifreeze starts
4
Changing the water set point on the basis of the temperature taken by
the thermostat
This code provides the information whether the mode is activated:
Night/Reduction of the frequency
1. Not active
2. Active
6
Value of the compressor's frequency reduction in %
7 Lock
The control panel displays these parameters
1. At home
2. Night
3. Away from home
8 Lock
This code is the control room set point determined by pressing the
home, night, away buttons
9 Lock
This is the room air temperature read by the thermostat sensor
10 Lock
This is the relative humidity value from the thermostat sensor
11 Lock
Outdoor Temperature measured by the sensor
12 Lock
Outdoor temperature read by the GMC board
13
Correction of the temperature read to correct errors due to the position
of the thermostat.
14
This parameter specifies the number of periods per day that should be
activated for the timing programme:
2
4
6
15
AT HOME set point temperature in heating mode
16
AT HOME set point temperature in cooling mode
17
NIGHT set point temperature in heating mode
18
NIGHT set point temperature in cooling mode
19
AWAY FROM HOME set point temperature in heating mode
20
AWAY FROM HOME set point temperature in cooling mode
21 Lock
Room set point
22 Lock
Shows the last alarm code
23 Lock
Shows the 4 most recent error codes
HYDRONIC UNIT LE B
Current mode
antifreeze:
Arrow depending
on the Touch 'N
Go selected
°C and the At
Home arrow
°C and the At
Home arrow
°C and the
night arrow
°C and the
night arrow
°C and the away
from home arrow
°C and the away
from home arrow
Icon
Value range
Set
value
Min
Max
-
-
0
1
2
1
°C
6°C
12°C
6°C
°C
-5°C
+5°C
0°C
1
2
1
50% 100% 100%
1
3
1
°C
12°C 38°C
20°C
°C
-20°C 50°C
%
0
100
°C
-30°C 90°C
°C
-20°C 65°C
°C
-5°C
5°C
0°C
2
6
4
12°C 38°C
20°C
12°C 38°C
24°C
12°C 38°C
18°C
12°C 38°C
26°C
12°C 38°C
15°C
12°C 38°C
28°C
°C
12°C 38°C
20°C
-
-
-
-