HYDRONIC UNIT LE B
A
Unit
B
Control panel
S1
OFF (open contact) - ON (closed contact)
S2
Cooling (open contact) / Heating (closed contact)
S3
Normal (open contact) / Eco (closed contact)
3-way valve (only N-10 for spring models) (18-N: Power supply; 10:
1
Signal)
2
Auxiliary heat source required for DHW / Dehumidification
3
Additional water circulator / Water pipe trace heaters
4
External heat source / Defrosting
5
Alarm / Signal that Ambient Temperature has been Reached
6
Maximum frequency reduction
7
Domestic water requested
8
External alarm input
9
External temperature sensor (NTC 3k @25°C)
RS485 (Green)
only Technical Service use
seulement pour le Service Technique
Remote control
A
4 B - 6 B - 8 B - 12 B
All manuals and user guides at all-guides.com
G
G
N
N
Beretta
Riello Remote
Remote
control
control
C
W
G
Y
13
B
single-phase / monophasée
L
N
A
Unité
B
Panneau de commande
S1
OFF (contact ouvert) - ON (contact fermé)
S2
Climatisation (contact ouvert) / Chauffage (contact fermé)
S3
Normal (contact ouvert) / Eco (contact fermé)
Vanne à 3 voies (uniquement N-10 pour modèles à ressort) (18-N:
1
Alimentation; 10: Signal)
Demande source de chaleur complémentaire pour ECS /
2
Déshumidification
3
Circulateur d'eau supplémentaire / Résistances de traçage tuyaux d'eau
4
Source de chaleur externe / Dégivrage
5
Alarme / Signal de température ambiante atteinte
6
Réduction fréquence maximale
7
Demande d'eau sanitaire
8
Entrée alarme externe
9
Capteur de température externe (NTC 3k @25°C)
18
10
11
12
4
5
16
1
4
2
5
3
14
15
7
6
3
2
1
8
6
7
S3
L N
10
10
40
30
Gateway
Supply
L
N
L
N
G
1
-
2 GND
1 2 3
3
+
9
8
21
23
24
S1
S2
37