8.4) PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
The following tables describe the functions available on the control unit.
MENU
Automatic closing time. Enabled only with logic "TCA"=ON.
TCA
At the end of the set time, the control unit commands a closing maneuver .
tped
The passage left open by the gate leaf during the partial opening (pedestrian) is adjusted.
fsto
The opening speed is adjusted. *
fstc
The closing speed is adjusted. *
sldo
Adjusts the slowdown speed of sliding door during the opening phase* (Fig.10 -slow Open).
sldc
Adjusts the slowdown speed of sliding door during the closing phase * (Fig.11 -slow Close).
Sets the starting point of the slowdown during the opening phase (Fig.10- beginning of the slow
tsmo
Open). The value is expressed in percentage on the entire stroke. *
Sets the starting point of the slowdown during the closing phase (Fig.11- beginning of the slow
tsmc
Close). The value is expressed in percentage on the entire stroke. *
PMO
Adjusts the motor torque applied to sliding door during the opening phase.
PMC
Adjusts the motor torque applied to sliding door during the closing phase.
Adjusts the motor torque applied to sliding door during the slowdown in opening phase (Fig.9
PSO
- Slow Open).
Adjusts the motor torque applied to sliding door during the slowdown in closing phase (Fig.10
PSC
- Slow Close).
Adjusts the stopping distance after the closing and opening limit switches have been inter-
cepted.
blc
Function only active when deceleration is enabled.
0: Minimum deceleration distance
5: Maximum deceleration distance.
Activation time of the courtesy light contact. Value expressed in seconds. At the beginning of
tls
each maneuver the contact latches for the set time. See the description of AUX1 parameter.
Activation time of AUX1/AUX outputs when set as a second radio channel.
T2ch
0: Bistable output, the output status switches each time a command is received.
1-250: Switching time in seconds
Selects the operation mode of AUX1 output:
0: Gate open indicator light. The light is off when the door is closed, flashes when the door is
moving, is on when the door is open.
1: Second radio channel. The output is controlled by the radio channel of the built-in receiver
(see RADIO menu).
2: Service light. The contact closes for the time set with the TLS parameter. Counting starts
aux1
with the beginning of the operation.
3: Zone light.
4: Phototest. Used to power the photocell transmitters in TEST mode.
See connection diagram Fig.23.
ATTENTION: LED lamps 24Vdc, due to the inrush current, cannot be connected directly
to the AUX1/2 outputs, use a decoupling relay.
aux2
Same operation features as AUX1 output, but referred to terminals AUX2.
* ATTENTION: A WRONG SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
RESPECT THE REGULATION IN FORCE!
Measure that impact forces comply with the values laid down in regulation en 12445. change, if necessary, the operating parameters and repeat the measurements.
Once you have manually modified the parameters SLDO/SLDC the controller performs a complete manoeuvre to learn the new parameters.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
IbL
effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal has no
ibca
effect during the TCA counting.
Off: the bloc of flat function is disabled.
8.4.1) PARAMETERS (PAR)
FUNCTION
8.4.2) LOGICS (LOG)
FUNCTION
MEMO
MIN-MAX-(Default)
3-240-(40)
10-99-(50)
50-99-(99)
50-99-(99)
10-50-(25)
10-50-(25)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
0-5-(0)
1-240 (60)
0-250-(1s)
0-4-(0)
0-4-(1)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
25