Installation Site - AEG WSP 2010 Notice D'utilisation Et De Montage

Accumulateurs de chaleur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For the Fitter

2.4 Installation Site

The unit may not
– be operated in rooms where there is a risk of fire or explosion due to chemicals, dust, gases or
fumes;
– be operated in the immediate vicinity of pipes or containers which carry or contain inflammable
or explosive substances;
– be operated when the minimum distances from adjacent object surfaces are not kept.
In rooms in which exhaust fumes, oil and petrol smells occur, the unpleasant smell may linger and
could possibly cause soiling.
Installation wall
Check whether a wall of sufficient stability is available for fastening the unit.
If no suitable fastening wall is available, the unit must be fixed to the floor (screwed directly to the
floor or to another floor console [special accessory]).
Floors
The standing surface of the unit must be level and sufficiently stable so that the housing is not
deformed.
A temperature resistance of the fastening wall of at least 85 °C and of the floor of at least 80 °C
must be ensured. The units can be placed on any conventional floor but changes may occur in the
rail area on PVC, parquet and long pile carpeted floors under the influence of pressure and tem-
perature. In this case heat-resistant underlay tiles must be used (to be provided on site).
2.5 Unit Installation (fig. 3-14)
The storage heater must be secured by a wall or floor fixture (fig. 8) to meet the VDE standing
safety requirement.
The screws and plugs necessary for fixing the unit are not included in delivery. They must be
selected and provided by a qualified fitter depending on the respective wall material.
Wall fastening
There is a hole in the unit rear wall in the vicinity of the switching area through which a suitable
screw can be inserted for fixing to a sufficiently stable wall (fig. 8).
Before fixing the unit, make sure that the permissible minimum distances from adjacent objects
are kept.
Floor fastening
The unit is fixed to the floor by screwing the bottom of the unit to the floor through 4 9 mm holes
(see "Technical Data", page 9 for dimensions).
This type of fixture is only possible with the air outlet and inlet grilles and the fan drawer removed.
26

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wsp 3010Wsp 4010Wsp 5010Wsp 6010Wsp 7010

Table des Matières