USING THE APPLICANCE
NOTE:
The appliance can only be used if the pa-
per bag is inserted correctly.
-
The appliance is fitted with wheels and
can therefore be pulled along using the
flexible hose.
-
To lift it up, insert your fingers into the
handle (15 Fig. 10) on the top of the cov-
er.
Starting up the appliance
-
Insert the plug (16 Fig.11) into the electri-
cal socket; the switch (17 Fig. 9) will light
up.
-
Press the switch (17 Fig. 9) on "I", and the
appliance starts up.
NOTE:
The suction force can be adjusted using the
selector (18 Fig. 12) located on the ergonom-
ic handle (10 Fig. 12).
Opening up the window (19 Fig. 12) results in
lower suction power.
Using the telescopic tube (if present)
-
The length of the telescopic tube (20 Fig.
13) can be adjusted as follows:
-
To lengthen the tube, press down on the
ring nut (21 Fig. 13) with your finger and,
at the same time, remove the upper part
(22 Fig. 13) of the tube; when the desired
length is reached, release the ring nut (21
Fig. 13) the tube will lock into the nearest
locking position;
-
To shorten the telescopic tube, use one
hand to press down the ring nut (21 Fig.
13) and with the other hand reinsert the
upper tube (22 Fig. 13) into the lower
sleeve (23 Fig. 13).
Switching off the appliance
-
Press the switch (17 Fig. 9) to "0" switch
off the appliance.
-
Remove the plug (16 Fig.11) from the
socket.
-
Wind up the cable (24 Fig. 14) and hook
it in position then hook the hose (11 Fig.
14) to the joint.
CLEANING AND
MAINTENANCE
DANGER:
Before performing any maintenance op-
erations, unplug the appliance from the
socket.
Removing and replacing the paper
dust collection bag.
-
Release the levers (1 Fig. 1) and remove
the cover (2 Fig. 2) complete with motor.
-
Remove the polyester (3 Fig. 2) filter (if
any)
-
Remove the paper dust collection bag (4
Fig. 3) and replace it as indicated above.
-
Reassemble all the parts carrying out the
dismantling procedure steps in reverse
order.
Checking and cleaning the cartridge
filter (if present)
-
Release the levers (1 Fig. 1) and remove
the cover (2 Fig. 2) complete with the mo-
tor and cartridge filter (25 Fig. 15).
-
Unscrew the central knob (26 Fig. 15)
and remove the filter cartridge (25 Fig
15).
-
Clean the filter (25 Fig. 16) from the in-
side out with a blast of air. If there is too
much dirt, it must be replaced.
-
Reassemble all the parts by following the
dismantling process steps in the reverse
order.
ENGLISH - 2
www.ghibliwirbel.com
Professional Cleaning Machines Since 1968