The following diagram is for informational purposes only. These locations are not the only points to check
•
nor the only potential areas for a gas leak to be present. Ensure the leak test includes all valves, pipe
connections, joints, lines and every point from the gas source to the burners.
UNPACKING UNIT:
Product Inspection:
Please re-check for possible shipping damage immediately after unpacking your grill. If the appliance is found to have
some damage, contact your dealer immediately as often the shipping carrier will have a timeframe to report damage.
Please also save the packaging material the product came with as that is at times inspected by the shipping carrier.
Caution: Do not leave the unit under the sun with the protective film on for a long period of time as it will make the film
difficult to remove and/or leave markings on the materials which are not covered by the warranty.
Your Blaze Series Appliance comes pre-assembled and requires very little setup. We do however; recommend the use of
professional help during the installation of your unit as improper installation may affect your warranty. Remove the unit
from the box along with all accessories and check that no damage has occurred to the unit or any parts. Remove all
packaging materials, labels and protective plastic film before you start cooking.
Burners: Check the burner tubes and remove any obstructions that may be in the ports or holes. Using cold water and a
brush will be sufficient. Make sure all foreign particles are removed from the burner before use. Make sure the air shutter
on the burners is slightly opened (to about 1/8" for NG and 1/4" for LP). When finished ensure that the burners are aligned
with the valve orifice and seated in the bracket slot. This is accomplished by first placing the burner tube shutter hole
securely over the valve orifice and ensuring the male post on the burner rests in the corresponding slot in the rear of the
grill chassis. Failure to do so could result in a fire and injury.
NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
A final inspection of your product occurs at the factory to ensure a quality product is packaged.
Blaze Instructional Book
Page | 17