V 2.5
REPLACING CARBON BRUSHES
NOTE: Always replace all carbon brushes at the same time.
1.
Using the included parts list, locate the carbon brushes.
2.
Remove the screws from the body.
3.
Pry the main body of the tool open using a flat head screwdriver.
4.
Remove the old brushes.
5.
Insert the new brushes.
6.
Run the motor for at least 15 minutes without load to align the new brushes
with the commutator.
LUBRICATION
All bearings in this tool are lubricated with a sufficient amount of high grade lubricant for the life of the
tool under normal conditions. Therefore, no further lubrication is required.
DISPOSING OF TOOL
If your tool has become damaged beyond repair, do not throw it out. Bring it to the appropriate
recycling facility.
TROUBLE SHOOTING
If the tool does not function properly or if it is missing parts, contact Princess Auto Ltd. for a solution. If
unable to do so, have a qualified technician service the tool.
Problem(s)
The tool will not operate
The wheel moves slowly
Smoke results from
operation of the tool.
18
All manuals and user guides at all-guides.com
5 in. Angle Grinder
Possible cause(s)
Power supply is incorrect for the
tool's electrical rating.
Tool is not properly attached to
the power supply.
The wheel may not be
securely attached
The tool components may
need cleaning.
There is a buildup of rust or
debris in the wheel.
For technical questions call: 1-800-665-8685
Suggested solution(s)
Plug the tool into a 120V 60 Hz
power supply
Ensure that the tool's power cord
is connected securely to the power
supply and that the cord is not
damaged in any way.
Tighten the nut that attaches the
wheel to the spindle.
Disconnect the tool from the power
supply and clean the components of
the spindle.
Immediately switch off the tool and
disconnect from power
supply. Remove the wheel from
the spindle and clean all
components thoroughly.
8336174