Electrical Connection - AGA MARVEL 60RDE Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Figure 4
Do not splash or spray water from a hose on the refrigera-
tor! Doing so may cause an electrical shock, which may
result in severe injury or death.
This unit should not, under any circumstances, be installed
to an un-grounded electrical supply.

Electrical Connection

A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that
has a three-pronged, grounded plug. It must be plugged into a
mating grounding type receptacle in accordance with the Na-
tional Electrical Code and applicable local codes and ordinances
(see Figure 3). If the circuit does not have a grounding type re-
ceptacle, it is the responsibility and obligation of the customer to
provide the proper power supply. The third ground prong should
not, under any circumstances, be cut or removed.
ELECTRICAL CONNECTION
Toe kick (Front Grille)
Toe kick screw
Do not use an extension cord
with this appliance.
The unit must be installed according to your local building codes
and ordinances.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nuisance
tripping which will cause the unit to shut down. GFCI's are gener-
ally not used on circuits which power equipment that must run
unattended for long periods of time, unless required to meet
local building codes and ordinances.
Figure 6
5
Figure 5
Anti-Tip device

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Marvel 60rdepMarvel 80rdeMarvel 6orde

Table des Matières