SPECIFICATIONS
Installation Requirements
IMPORTANT NOTE:
When installing against a combustible
surface, a minimum 254 mm riser is required for a 914 mm
dual fuel range with charbroiler or griddle and all 1219 mm
and 1524 mm models.
4 | English
Electrical
Installation must be electrically grounded (earthed) in accor-
dance with local codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on page 5.
REQUIRED POWER SUPPLY
Single phase
220-240V AC, 50/60 Hz
3phase
380-415V AC, 50 Hz
MAXIMUM CONNECTED LOAD
DUAL FUEL RANGES
SINGLE PHASE
762 mm and 914 mm
19 amps
18 amps
1219 mm
35 amps
18 amps
1524 mm
38 amps
18 amps
Connection of this appliance should be
IMPORTANT NOTE:
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
Gas Supply
Installation must conform with local codes.
Locate the gas supply within the shaded area shown in the
illustration on page 5.
The range is equipped for use with natural or liquid propane
(LP) gas. The product rating plate has information on the
type of gas that should be used. For rating plate location,
refer to the illustration below. If this information does not
agree with the type of gas available, check with the local
gas supplier.
HEAT OUTPUT
3PHASE
Surface Burners
Surface Burner
with .1 kW (7 g/h) delivered at
Optional Infrared Charbroiler
Optional Infrared Griddle
Optional French Top
RATING PLATE
Rating plate location.
IMPORTANT NOTE:
The dual fuel range must be connected
to a regulated gas supply.
The rating plate, located at the far right of the bottom of
the control panel assembly just above the oven door, has
information on the type of gas that should be used. If this
information does not agree with the type of gas available,
check with the local gas supplier.
A compatible ISO 7-1 gas inlet thread is provided on all
units. Please contact your local Wolf dealer if an ISO 228-1
or other gas inlet thread is required. Pipe joint compounds,
suitable for use with LP gas should be used. For LP gas,
4.8 kW (291 g/h)
piping or tubing size can be 13 mm minimum. LP gas sup-
with .3 kW (22 g/h)
pliers usually determine the size and materials used on the
delivered at simmer
system.
2.7 kW (178 g/h)
If local codes permit, a flexible metal appliance connector is
recommended for connecting this range to the gas supply
simmer and melt feature
line. Do not kink or damage the flexible connector when
5.6 kW (374 g/h)
moving the range.
5.6 kW (374 g/h)
If rigid pipe is used as a gas supply line, a combination of
4.8 kW (291 g/h)
pipe fittings must be used to obtain an in-line connection to
the range. All strains must be removed from the supply and
gas lines so the range will be level and in line.
Wolf natural gas ranges will function up to 3124 m in altitude
without adjustment and LP gas ranges will function up to
2621 m. If the installation exceeds these elevations, contact
your authorized Wolf dealer for a high altitude conversion
kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve.