Lubrication and oil

AIr CoMPrEssor

The air compressor pump was filled WItH oil at the manufacturer.
Check air compressor pump oil level before operating unit. See
Compressor Pump oil under Maintenance.

Grounding Instructions

WARNING: Risk of electrical shock. In the event of a short
circuit, grounding reduces the risk of shock by providing an escape
wire for the electric current. This air compressor must be properly
grounded.
The portable air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug.
1. The cord set and plug (N) with this unit
contains a grounding pin (O). This plug
Must be used with a grounded outlet
(P).
IMPortAnt: The outlet being used must
be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood, or
if in doubt as to whether the compressor is properly grounded,
have the installation checked by a qualified electrician.
DANGER: Risk of electrical shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
• Do not modify the plug provided. If it does not fit the available
outlet, a correct outlet should be installed by a qualified
electrician.
All manuals and user guides at all-guides.com
• Repairs to the cord set or plug MUST be made by a qualified

Extension Cords

Using extension cords is not recommended. The use of extension
cords will cause voltage to drop resulting in power loss to the motor
and overheating.
Instead of using an extension cord, increase the working reach of
the air hose by attaching another length of hose to its end. Attach
additional lengths of hose as needed.
If an extension cord must be used, be sure it is:
• a 3­wire extension cord that has a 3­blade grounding plug, and
• in good condition
• no longer than 50 feet (15.2 m)
• 12 gauge (AWG) or larger. (Wire size increases as gauge num-
P
N

voltage and Circuit Protection

O
Refer to Voltage and Minimum Branch Circuit requirements
under Motor Specifications.
CAUTION: Certain air compressors can be operated on a
20 amp circuit if the following conditions are met.
• Voltage supply to circuit must comply with the National Electrical
Code.
• Circuit is not used to supply any other electrical needs.
• Extension cords comply with specifications.
• Circuit is equipped with a sufficient size circuit breaker or time
delay fuse for the motor set up, see Motor Specifications. notE:
If compressor is connected to a circuit protected by fuses, use
only time delay fuses. Time delay fuses should be marked "D" in
Canada and "T" in the US.
11
electrician.
a 3-slot receptacle that will accept the plug on the product
ber decreases. 10 AWG and 8 AWG may also be used. DO NOT
USE 14 OR 16 AWG.)