Maintenance Chart

Procedure
Daily
Check safety valve
X
Inspect air filter +
Drain air tank***
X
Check pump oil level
X
Change pump oil** +
Oil leak inspection
X
Inspect drive belt
X
Check drive belt tension
Check pulley/flywheel
alignment
Check for unusual noise/
X
vibration
Check for air leaks*
X
Clean compressor exterior
* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
All manuals and user guides at all-guides.com
WALT autho-
e
Weekly Monthly
1 year or
200 Hours
X
X
X
X
X
** The pump oil must be changed after the first 20 hours or operation.
D
WALT
Thereafter, when using
e
every 200 hours of operation or once a year, whichever comes first.
*** Drain tanks daily or after four hours of use.
+ Perform more frequent in dusty or humid conditions.
Checking Safety valve (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.
WARNING: Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or
an explosion.
Before starting compressor, pull the ring on the safety valve to
make sure that the safety valve operates freely. If the valve is stuck
or does not operate smoothly, it must be replaced with the same
type of valve.
Checking Air Filter Element (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to
servicing.
1. Ensure On/Off switch is in the OFF position.
2. Allow unit to cool.
3. Remove filter (A) top from filter base by turning filter counter-
clockwise about 5 degrees.
4. Separate filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if needed.
16