Wiring Instructions; Grounding Instructions; Voltage And Circuit Protection - DeWalt DXCMLA3706056 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

properly mounted.
The air compressor MUST be bolted to a level, solid concrete
surface. Use 3/8" lag screws, vibration pads and concrete
anchors. If help is needed anchoring the air compressor consult
a licensed contractor.
1.
Place
the
air
compressor on a
Vibration
level, solid concrete
surface. Make sure
the concrete is in
supplied)
good condition with
no
cracks
or
damage.
2.
Mark the surface
Shim Under
using the holes in
Vibration pad
the air compressor
(not supplied)
feet as a template.
3.
Drill holes in the
surface for the concrete anchors. Install concrete anchors.
4.
Line-up holes in surface with holes in air compressor feet.
5.
Place the vibration pads (not supplied) between the floor and
air compressor feet, see figure. If needed use shims to level
the unit.
6.
Place the 3/8" lag screws through the air compressor feet,
vibration pads and into the anchors.
7.
Torque 3/8" lag screws to 7-10 ft.-lbs (9.5-13.5 Nm).

Wiring Instructions

WARNING:
Improper electrical installation of this product
may void its warranty and your fire insurance. Have circuit wiring
performed by qualified personnel such as a licensed electrician
3/8" Lag
Screw
pad
(not supplied)
(not
Surface Line
Concrete Anchor
(not supplied)
who is familiar with the current national electrical code and any
prevailing local electrical codes.
WARNING:
Risk of electrical shock. Improper electrical
grounding can result in electrical shock. The wiring should be
done by a qualified electrician.
A qualified electrician needs to knows the following before wiring:
1.
The amperage rating of the electrical box should be adequate.
Refer to the air compressor's serial label for the unit's voltage
and amperage requirements.
2.
The supply line should have the same electrical characteristics
(voltage, cycle, phase) as the motor. Refer to the motor
nameplate, on side of motor, for this information.
NOTE: The wiring used must be rated for the motor nameplate
voltage, plus or minus 10%. Refer to local codes for recommended
wire sizes, correct wire size, and maximum wire run; undersize wire
causes high amp draw and overheating to the motor.
WARNING: Risk of electrical shock. Electrical wiring must be
located away from hot surfaces such as manifold assembly,
compressor outlet tubes, heads, or cylinders.

Grounding Instructions

This product should be connected to a metallic, permanent wiring
system, of and equipment-grounding terminal or lead on the
product.

Voltage and Circuit Protection

Refer to the Voltage and Minimum Branch Circuit Requirements
under Specifications.
CAUTION: Certain air compressors can be operated on a
15 amp circuit if the following conditions are met.
12

Publicité

Table des Matières
loading

Table des Matières