adjusting cams for limit switch contacts
Cam
Key
Adjustment travel
Fig. 14:
Adjusting limit switch
clockwise
procedure:
Adjust the two upper cams with a suitable key (see "Fig. 14" and
"Fig. 15").
On completion of the adjustment work, re-attach the hood 3, the
position indicator, the seal and the glass hood 1.
The rotary actuator is supplied ex works with the following
settings:
• The limit switch CLOSED (FCF) is actuated by the cam
(closed position).
• The limit switch OPEN (FCO) is preset to a rotation
angle of 90°.
18
Cam
Key
Adjustment travel
Fig. 15:
Adjusting limit switch
anti- clockwise
english
Type 3005

Installation

9.
installation
9.1. safety instructions
Warning!
Danger - improper installation!
Improper installation may result in injuries as well as damage to
the device and the area around it.
• Fluid and electrical installations may be carried out by author-
ised technicians only and with the appropriate tools!
Danger due to unintentional activation of the equipment!
Unintentional activation of the equipment during installation work
may result in injuries and/or damage.
• Take appropriate measures to prevent the equipment from being
unintentionally activated.
9.2. electrical installation
Danger!
risk of electric shock!
There is a serious risk of injury when reaching into the device.
• Before starting work, always switch off the power supply and
safeguard to prevent re-activation!
• Observe applicable accident prevention and safety regulations
for electrical equipment!
• Attach earthing cable via the earthing screw!