A correct fit of the unit and ingress resistance of the connection are only ensured
using Krohne adapters.

6 Electrical connection

The unit must be connected by a qualified electrician.
Voltage supply according to EN 50178, SELV, PELV.
► Disconnect power.
► Connect the unit as follows:
Colours to DIN EN 60947-5-2
BK: black; BN: brown; BU: blue; WH: white
Pin
Connection
4
• switching signal for volumetric flow
(OUT1)
• switching signal for temperature
• switching signal for volumetric flow direction
• switching signal for preset counter
• pulse signal for quantity meter
• frequency signal for volumetric flow
• frequency signal for temperature
• IO-Link
• OFF
2
• switching signal for volumetric flow
(OUT2/InD)
• switching signal for temperature
• switching signal for volumetric flow direction
• analogue signal for volumetric flow
• analogue signal for temperature
• input for external meter reset signal (InD)
• OFF
1
BN
L +
2
WH
OUT2
4
BK
OUT1
3
BU
L