LASER SAFETY
The use of controls, adjustments, or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Do not stare into the laser beams. Do not disassemble the instrument or
attempt to perform any internal servicing.
Repair and servicing of this laser are to be performed only by CST or author-
ized service centers.
This laser complies with all applicable portions of title 21 of the Code of
Federal Regulations set by: the Dept. of Health, Education, and Welfare; the
Food and Drug Administration; the Center for Devices; and the Bureau of
Radiological Health.
The laser LM30 has also been tested and complies with the CE certification
requirements set forth in the EC regulations 89/336/EEC and EN 61000-6-1
(EN50082-1), EN 61000-6-3 (EN50081-1) and IEC 60-825-1.
OPERATION
Basic Leveling
As with any level referencing instrument, checking calibration before each
use is recommended.
1.
Set the instrument on any smooth surface, or mount to a 5⁄8" x 11 tripod
and adjust to desired height.
2.
Use the leveling screws and level vials to level the instrument. Each lev-
eling screw controls the vial opposite the screw (the front leveling
screw controls the "Y" axis, and the side leveling screw controls the
"X" axis).
LM30 Rotary Laser • 5