ERROR MESSAGE
 The error messages are shown on the display.
Er2
The gearmotor's auto-learning of the gate travel is interrupted; check whether the motor is properly connected and
functioning.
Er3
Encoder is broken.
Services-test error; check whether the safety devices are properly connected and functioning.
Er4
Er5
Insuffi cient operating time; check the F22 set time, it may need extending to complete the duty cycle.
Er6
Maximum number of obstructions detected.
Overheated transformer - the gate leaves stay open after an "open" command.
Er7
CO
Contact 1-2 (STOP) unused; deactivate the contact from function F1.
Contacts CX and/or CY unused: deactivate contacts from functions F2 and/or F3.
C1/2/3/4
 Red LED fl ashing; the control board has no auto-learning.
FINAL OPERATIONS
Once the connections are done and the operator is up and running, fasten the bottom cap to the gearmotor and the control panel
cover by using the screws
.
CABLE GLAND
UNI 6954 3.9x13