F23
Do not modify. Function unavailable.
F24
Do not modify. Function unavailable.
F25
Do not modify. Function unavailable.
F26 Ramming thrust time
After an opening or closing command, the gearmotor thrusts inward for an adjustable time between one and two seconds.
F27 Lock time
After an opening or closing command, the electric lock releases for an adjustable time between one and four seconds.
F28
Do not modify. Function unavailable.
F29 Gearmotor's maneuvering speed
Setting the opening and closing speeds of the gearmotor, calculated as a percentage.
F30
Do not modify. Function unavailable.
F31 Gearmotor's slow-down speed
Setting the opening and closing slow-down speed of the gearmotor, calculated as a percentage.
F32
Do not modify. Function unavailable.
F33 Auto-learning speed
Setting the gearmotor's speed, calculated as a percentage, during the auto-learning phase, .
F34 Travel sensitivity
Adjusting obstruction detection sensitivity during gate travel.
F35 Slow-down sensitivity
Adjusting obstruction detection sensitivity during slow-down.
1= 1 second (default) / 2= 2 seconds
1= 1 second (default) / 4= 4 seconds
40= Minimum speed /... / 100= Maximum speed (default)
20= Minimum speed /... / 50= Speed (default) /... / 60= Maximum speed
30= Minimum speed /... / 50= Speed (default) /... / 60= Maximum speed
10= Maximum sensitivity /... / 100= Minimum sensitivity (default)
10= maximum sensitivity /... / 100= minimum sensitivity (default)