ILLUSTRATION OF THE SLOW-DOWN POINTS AND END-STROKE AREAS
 The areas where the gate-leaf travels and the slow-down points and end-strokes are tested according to the parameters provided
by Technical Standard EN 16005 regarding the compatibility of impact forces generated by the moving leaf.
A = Movement area at normal speed.
B* = Movement area at slowed-down speed.
C = Encoder intervention zone with movement inversion.
D = Encoder intervention zone with movement stopped.
* Minimum 600 mm from the strike plate.
** Set the end-stroke percentage for function F 43 - F 44 so as to achieve a distance of less than 50 mm from the positive stop.
E* = Opening slow-down starting point.
F* = Closing slow-down starting point.
G** = Opening end-stroke starting point.
H** = Closing end-stroke starting point