Section 4
CLEANING/SANITIZING PROCEDURE RN0400
Use Ice Machine Cleaner part number 000000084.
Use Ice Machine Sanitizer part number 94-0565-3.
Step 1 Disconnect power, remove front, top and right
panels and set the compressor rocker switch to the OFF
position.
Step 2 Remove all ice from the bin/dispenser.
Step 3 Turn off the ice making water supply.
Step 4 Drain water from evaporator and reservoir
through the evaporator/reservoir drain line and reinsert
hose into hose clip.
Step 5 Follow the chart and premix cleaner and water.
Amount of Luke Warm Water
1 gallon (4 Liters)
Step 6 Remove top cover from the water reservoir and
fill the evaporator and reservoir with cleaning solution.
Remainder of solution will be used for hand cleaning.
Step 7 Verify the compressor rocker switch is in the
OFF position, then reconnect power and run the
gearmotor for 15 minutes. Perform the following
procedures during the 15 minute period:
•
Remove ice compression nozzle from evaporator
and soak in cleaning solution.
•
Descale drain pan by gently flexing, then remove any
scale residue.
•
Inspect water feed and drain lines and clean as
needed.
•
Connect ice transport tube direct to evaporator and
secure with hose clamp.
Part Number 000007282 4/10
Amount of Cleaner
Part Number 000000084
4 ounces (120 ml)
Step 8 Disconnect power, then drain the water from the
evaporator and reservoir through the evaporator/
reservoir drain line - Using a pitcher, fill and drain the
evaporator/reservoir 4 times and reinsert the hose into
the hose clip.
Step 9 Refer to chart and premix water and sanitizer.
Amount of Luke Warm Water
1 Gallon (4 L) Water
Step 10 Fill reservoir and evaporator with sanitizer/
water solution.
Step 11 Verify the compressor rocker switch is in the
OFF position, then reconnect power and run the
gearmotor for 10 minutes.
•
During the 10 minute period rinse cleaner from
compression nozzle with potable water and then
soak in sanitizer/water solution.
Step 12 Move the compressor rocker switch to the ON
position. The ice machine will make ice with the
sanitizer/water solution and deposit the ice in the bin/
dispenser. Make ice for 5 minutes - add sanitizer/water
solution as the water level in the reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop
below the sensing probes. The ice machine will start a
20 minute delay period if the sensing probes lose
contact with the water for more than 10 seconds.
Maintenance
Amount of Sanitizer
1/2 ounce (15 ml)
Continued on next page ...
21