Section 4
CLEANING/SANITIZING PROCEDURE RN0400
Use Ice Machine Cleaner part number 000000084.
Use Ice Machine Sanitizer part number 94-0565-3.
Step 1 Disconnect power, remove front, top and right
panels and set the compressor rocker switch to the OFF
position.
Step 2 Remove all ice from the bin/dispenser.
Step 3 Turn off the ice making water supply.
Step 4 Drain water from evaporator and reservoir
through the evaporator/reservoir drain line and reinsert
hose into hose clip.
Step 5 Follow the chart and premix cleaner and water.
Amount of Luke Warm Water
1 gallon (4 Liters)
Step 6 Remove top cover from the water reservoir and
fill the evaporator and reservoir with cleaning solution.
Remainder of solution will be used for hand cleaning.
Step 7 Verify the compressor rocker switch is in the
OFF position, then reconnect power and run the
gearmotor for 15 minutes. Perform the following
procedures during the 15 minute period:
Remove ice compression nozzle from evaporator
and soak in cleaning solution.
Descale drain pan by gently flexing, then remove any
scale residue.
Inspect water feed and drain lines and clean as
needed.
Connect ice transport tube direct to evaporator and
secure with hose clamp.
Part Number 000007282 4/10
Amount of Cleaner
Part Number 000000084
4 ounces (120 ml)
Step 8 Disconnect power, then drain the water from the
evaporator and reservoir through the evaporator/
reservoir drain line - Using a pitcher, fill and drain the
evaporator/reservoir 4 times and reinsert the hose into
the hose clip.
Step 9 Refer to chart and premix water and sanitizer.
Amount of Luke Warm Water
1 Gallon (4 L) Water
Step 10 Fill reservoir and evaporator with sanitizer/
water solution.
Step 11 Verify the compressor rocker switch is in the
OFF position, then reconnect power and run the
gearmotor for 10 minutes.
During the 10 minute period rinse cleaner from
compression nozzle with potable water and then
soak in sanitizer/water solution.
Step 12 Move the compressor rocker switch to the ON
position. The ice machine will make ice with the
sanitizer/water solution and deposit the ice in the bin/
dispenser. Make ice for 5 minutes - add sanitizer/water
solution as the water level in the reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop
below the sensing probes. The ice machine will start a
20 minute delay period if the sensing probes lose
contact with the water for more than 10 seconds.
Maintenance
Amount of Sanitizer
1/2 ounce (15 ml)
Continued on next page ...