The remote control 
does not work.   
If problems not listed in the table occur or recommended solutions do not work, please contact 
the service centre. 
ERROR CODES 
Fault 
Fault Description 
Code 
F1 
Compressor IPM error 
F2 
PFC/IPM error 
F3 
Compressor start error 
F4 
Compressor running out of step 
F5 
Location detection loop failure 
F6 
PCB communication error
F8 
Sensor on suction pipe error
FA 
Phase current overcurrent protection 
FL 
Water‐full protection 
P1 
Over‐heat protection on top of compressor 
P2 
Dc bus voltage Undervoltage protection
P3 
AC Input voltage protection
P4 
AC over‐current protection
P5 
AC undervoltage protection
The remote control is not aligned with 
the direction of the remote‐control 
receiver. 
Batteries poor. 
Let the remote control get close to the air 
conditioner, and make sure that the 
remote control directly faces to the 
direction of the remote‐control receiver. 
Replace batteries. 
Fault 
Fault Description 
Code 
P6
Coil tube overload protection 
P7
Defrost protection on coil tube 
P8
Zero‐crossing fault detection 
Return air sensor temperature abnormal 
PA
protection 
 
PE
Abnormal refrigerant circulation 
PH
Exhaust temperature protection 
E0
Sensor on suction pipe error 
E1 
Temperature sensor error 
E2
Sensor error on indoor coil tube 
 
E3 
DC fan Feedback failure 
E5 
Water‐splash motor error 
E8
Fan feedback fault 
EE
EE error 