Installer And Maintenance Person Instructions; Water Connection - Adler DWA2050 Guide Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2

- INSTALLER AND MAINTENANCE PERSON INSTRUCTIONS

ATTENTION
Specialists that install the machine are
foreseen to train the operators about
machine utilization and safety procedures to
be followed. They must provide a real
"demonstration" and verify that machine
instructions are available to the operators.
Following attentions should be taken:
WARNING!
DO NOT OPEN THE DOOR QUICKLY IF CYCLE
IS NOT ENDED.
DO NOT DIP BARE HANDS IN WASHING
SOLUTION.
DO NOT TAKE OFF THE MACHINE PANELS IF
THE MACHINE HAS NOT BEEN DISCONNECTED
FROM THE POWER AND WATER SUPPLY.
DO NOT BYPASS THE MACHINE PROTECTIONS
(MICROSWITCHES,
PANELS,
PROVIDED BY THE MACHINE MANUFACTURER
IF NOT AT THE PRESENCE OF TRAINED
SPECIALISTS THAT CAN TAKE PROPRER
CAUTIONS.
DO NOT UTILISE THE MACHINE TO WASH
GOODS OUTSIDE THE SCOPE FOR WHICH IS
PROVIDED FOR, OBJECTS OF SHAPE, TYPE,
SIZE, AND MATERIAL NOT COMPATIBLE.
DO NOT OPERATE THE MACHINE IF NOT
PROPERLY CONNECTED, ACCORDING TO THE
SPECIFICATIONS AND REQUIREMENTS OF THE
LOCAL LAW AND PRESCRIPTION OF
MANUFACTURER, MAKING SURE THAT ALL
SAFETY DEVICES ARE OPERATIVE.
ID/RATING/DATA PLATE
ID/Rating plate of the appliance contains
identification and technical data and is located
on the front inside panel.
-
Extract the front panel with Allen tool or
similar by inserting it inside the holes on the
inferior part of the panel. Pull up the panel
carefully. For Hoodtype models, unscrew the two
screws located on the bottom of the panel.
(Fig.4)
Fig.4
2A - WATER CONNECTION
N.B.
Shut-off valve, single direction, spool,
sphere, lid control type, which can shut
water supply off quickly and totally,
selected to assure water pressure and flow
as requested in the data diagram supplied
with each machine.
1- Position the dishwasher and level the
appliance by turning the relative height-
adjustable feet. (Fig.5)
Fig. 5
2- Connect the solenoid valve, which feed
the machine, to water shut valve, using a
flexible line. (Fig.6) Each machine must
have its own water line supply.
OR
OTHERS)
Fig. 6
Check that dynamic water supply pressure,
measured between the appliance and the
main, is between 200 and 500kPa. If the
pressure is too high, fit a suitable pressure
reducer on the inlet pipe. If the pressure is
low,
pressure motor pump. (par.1D – Technical
Data)
- In case of new or long term appliance
inactivity, drain the water line to eliminate air
bubbles and foreign bodies present in new
or unused water lines, which can damage the
machine.
If water hardness is higher than acceptable,
install a water softener if in the machine is
not provided with an internal one, of
adequate size prior the feed solenoid valve.
(par.1D – Technical Data)
If there is a high concentration of mineral
residues in the water or high conductivity,
we
demineralization filter for 5/7° f.
2A1 – WATER SUPPLY PRESSURE
install
an
additional
2A2 – WATER HARDNESS
recommend
installing
external
the
7

Publicité

Table des Matières
loading

Produits Connexes pour Adler DWA2050

Ce manuel est également adapté pour:

Dwa3350Dwa2001Dwa5550Dwa2040Dwa3340

Table des Matières