3F - WARNING MESSAGES DISPLAYED
ON THE CONTROL PANEL
(Elettronic versions only)
N.B.
If the machine is in OFF mode, warning
messages are not visualized on the display.
Turn ON the machine to visualize type of error
or breakdown.
The following warning messages are visualized
on the display:
ntcb
E-01
BOOSTER TEMPERATURE PROBE
Booster temperature probe damaged or not
connected.
CALL TECHNICAL SERVICE ASSISTANCE
ntcu
E-02
TANK TEMPERATURE PROBE
Tank temperature probe damaged or not
connected.
CALL TECHNICAL SERVICE ASSISTANCE
FILL
E-03
WATER FILLING
Water filling process not completed on time
(max 10min).
Verify inlet main water supply is correctly
connected, open and free from any obstructions.
Verify solenoid valve filter is free from any
obstructions such as lime or scale.
Verify inlet water pressure corresponds to the
Technical Data. (see par.1D – Technical Data).
Verify the door is closed and the water flow
device is correctly positioned.
N.B.
If water filling time limit expires or filling
water level is lost, the solenoid valve closes
automatically the inlet water. To reset and
restart the solenoid valve press any button on
the control panel.
T bo
E-04
BOOSTER TEMPERATURE LIMIT
CALL TECHNICAL SERVICE ASSISTANCE
T UA
TANK TEMPERATURE LIMIT
E-05
CALL TECHNICAL SERVICE ASSISTANCE
drA
drA
E-06
DRAIN ANOMALY
E-06
Drain
anomaly,
water
completed during the time limit.
Verify water flow device is removed and
water drain line is free from any obstructions.
bnot
E-07
BOOSTER HEATING
Maximum booster heating time passed the
limit. (15min)
CALL TECHNICAL SERVICE ASSISTANCE
unot
E-08
TANK HEATING
Maximum tank heating time passed the limit.
(30min)
CALL TECHNICAL SERVICE ASSISTANCE
PARAMETER ERROR
SEruICE
SEruICE
E-09
E-05
ELECTRONIC CARD
FAILURE
Electronic card anomaly or failure.
CALL TECHNICAL SERVICE ASSISTANCE
FOLLOWING ACTIONS AFTER MACHINE
ERROR OR BREAKDOWN:
Booster and tank heating elements are
interrupted, water load is disactivated,
control panel display visualizes the error and
the electronic card is inactivated. All led
buttons are OFF. Washing cycle is interupted
(stanby mode) and restored if the problem is
solved. It is always possible to turn OFF the
machine by pressing button "A" ON/OFF, and
if the problem is solved, warning messages
are not more displayed.