Electrical Wtring
a. Wiring Precautions
� WARNING!
• Befare obtaining access to terminals, all supply circuits must be disconnected.
• T he rated voltage of the unit is as shown as table 7.
• Befare turning on, verify that the voltage is within the 198-264V range.
• Perform wiring work in accordance with standards so that the air conditioner can be
operated safely and positively.
Table 8
Model
09K
12K
18K
24K
36K
b. Electrical Wiring
1. For solid core wiring (Fig.29)
(1 ). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about
25mm (15/16") .
(2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
(3). Using pliers, bend the solid wire to farm a loop suitable for the terminal screw.
(4). Shape the loop wire properly, place it on the terminal board and tighten securely with the
terminal screw using a screwdriver.
2. For strand wiring (Fig.29)
(1 ). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about
10mm (3/8") .
(2). Using a screwdriver, remove the terminal screw (s) on the terminal board.
(3). Using a round terminal fastener or pliers, securely clamp a round terminal to each
stripped wire end.
(4). Position the round terminal wire, and replace and tighten the terminal screw with a
screwdriver.(Fig.30)
Power Supply
220-240V-,50Hz
220- 240V-,50Hz
220-240V-,50Hz
220- 240V-,50Hz
220- 240V-,50Hz
23
Recommended Cord
(piecesxsectional area)
2
4x0.75mm
2
4x0.75mm
2
4x0.75mm
2
4x0.75mm
2
4x0.75mm